Trakpower VR-1 Dual Racing Charger User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
13
G. IMPULSE CHARGE:
Refer to diagram at right.
This feature functions in Step Charge mode only,
and charges the battery at a current equal to
the charge current setting x 1.5 for 0.5 seconds,
every 3 seconds. The charge current at all other
times is as set in the Step Charge screen on page
12. The impulse charge method is much the
opposite of the refl ex charge method explained
below. Instead of applying high level negative
charge pulses to the battery for short intervals,
VR-1 applies high level positive charge pulses
at regular intervals. And as with refl ex mode,
the impulse method is believed by some to help clear a cell’s internal plates from build-up of
oxidizing gas bubbles, allowing the batteries to perform better. Decide which steps to have the
impulse mode function, which can be any combination of steps 1, 2 or 3. Impulse charge does
NOT function in step 4. See the diagram below for how to set this function.
i. Rotate dial to Impulse and place the cursor on step 1.
Press and rotate dial until the symbol appears next
to the 1.
ii. Rotate dial to move cursor to step 2. Press and rotate
dial until the ” symbol appears next to the 2. Press to
confi rm. Repeat for step 3 if desired.
H. REFLEX CHARGE:
As with the impulse charge mode, refl ex charge can be used in the Step Mode
charge mode. Decide which steps to have the refl ex charge mode function, which can be any
combinations of steps 1, 2 or 3. Refl ex charge does NOT function during step 4. Setting this
feature is the same as Impulse charge mode. See the above diagram for how to set this feature.
Note that impulse charge and refl ex charge can be applied to the battery at the same time!
To start step charge mode:
i. Press the jog dial once on the Step Charge icon. A delay
screen will appear showing all of the settings at the
bottom of the screen. If these settings are correct, either
allow the timer to expire or press and hold the dial to
begin. If these settings are incorrect, press ESC to back
out and make the necessary changes.
ii. Before the VR-1 begins the Step Charge process the
battery will perform a pre-discharge process. This
pre-discharge process discharges the battery to a safe
discharge level. Once the discharge cut-off voltage has
been reached there will be a 1 minute delay prior to
initializing the Step Charge.
iii. During the Step Charge process, the current step will be
displayed on the screen. See picture at right. There will
also be a one minute delay between each step.
IMPULSE CHARGE
7.5A
TIME
5A
0A
0.5 sec
Impulse current pulse
Normal charge
current setting
Page view 12